Senses the air temperature and cuts the heater if it gets too hot.
Tick the symptoms your appliance is showing. We’ll tell you how confident we are this part is the fix.
Error codes are model dependent, so the same brand may have more than one listed.
| Code | Brand | What it means | Confidence |
|---|---|---|---|
| F4 | Ariston | Means a heating circuit fault where the dryer cannot heat up or has detected a faulty water sensor, leading to cold air production. It is usually caused by a tripped thermostat, a faulty thermal fuse, or a damaged heating element. | High |
| F6 | Ariston | Means the thermal overload thermostat has tripped due to overheating, or the door switch is failing to register that the door is closed. It is usually caused by a heating circuit fault or a door lock issue. | High |
| F8 | Hotpoint | Means a heating circuit fault, where the heating element is energised when it should not be. It is usually caused by a faulty thermostat, thermal cut-out, or a malfunctioning control board. | High |
| F14 | Indesit | Means a heating circuit fault, specifically that the heating element is not activating. It is usually caused by a faulty heating element, a tripped thermostat, or faulty wiring or control board. | High |
| F4 | Indesit | Means a serious heating circuit fault that leaves the dryer producing no heat, usually within 3 to 5 minutes of operation. It is usually caused by a failed thermostat, a heating element, or a blocked airflow system causing overheating. | High |
Ariston
Means a heating circuit fault where the dryer cannot heat up or has detected a faulty water sensor, leading to cold air production. It is usually caused by a tripped thermostat, a faulty thermal fuse, or a damaged heating element.
Ariston
Means the thermal overload thermostat has tripped due to overheating, or the door switch is failing to register that the door is closed. It is usually caused by a heating circuit fault or a door lock issue.
Hotpoint
Means a heating circuit fault, where the heating element is energised when it should not be. It is usually caused by a faulty thermostat, thermal cut-out, or a malfunctioning control board.
Indesit
Means a heating circuit fault, specifically that the heating element is not activating. It is usually caused by a faulty heating element, a tripped thermostat, or faulty wiring or control board.
Indesit
Means a serious heating circuit fault that leaves the dryer producing no heat, usually within 3 to 5 minutes of operation. It is usually caused by a failed thermostat, a heating element, or a blocked airflow system causing overheating.
Don’t see your code? Different model years sometimes use different codes. Get in touch with our parts team and we’ll help you identify the right replacement.
General fitting guidance. The exact steps can vary slightly with the make and model of your tumble dryer.
Safety: Switch off and unplug at the mains and let it cool before you start.
Parts arrived within a few days. Parts were straight forward to fit. Much cheaper than a new dryer!
Found this part easily using the model number of my oven. Quick delivery
Great product, easy to replace, unfortunately the safety switch came already tripped, but the customer service was perfect sent a replacement with next day delivery A*****.
Ordered thermostat, easy to find the part. Quick delivery and easy to fit. Saved me a lot of money and realised I can actually fit these myself. Will definitely order again from this company
Brought these for my daughter & SO easy to fit & works PREFECT, would definitely recommend to anyone who has a tumble dryer blowing cold
Are there 2 thermostats in each ki?
Hi Thomas, there are 2 thermostats in this kit.